Industrial Ventilation.

What is Industrial Ventilation?

Air impurities and airborne contaminants become significant in concentration before entering the breathing zone of the worker is subjective to the air movement within the enclosed space. Ventilation influences the air in the concentration matriks of air impurity. It is used to capture the contaminant at source and to dilute the contaminant with effective air change within the enclosure. It can also be used to control indoor temperature, humidity, and air motion to benefit thermal comfort, satisfaction with other aspects of indoor environment or other objectives.

“Ventilation is the profound secret of existence.”

— Peter Sloterdijk

How we can help you.

 

Ventilation System Design

Using acceptable standards we design extraction hood at the point of contaminant generation or establish effective air change per hour for an enclosure which is very important in establishing the most effective control mechanism in air borne hazard control.

Air Cleaning Device

Identification of the air borne hazard is crucial for the design simulation process of a ventilation system name it local exhaust or general ventilation. Similarly the abatement process prior to the vertical discharge in the chimney, the suitable air cleaning device must be selected, design, constructed, commissioned and kick off operation with reliable predictive maintenance protocol. These air cleaning devices ranges from adsorption filters (activated carbon, Potassium Permanganate), scrubbers (spray chambers, packed towers, venturi), dust collectors (preliminary, fabric filter bag house, cyclones, multi cyclones).

Construction And Commissioning

We design exhaust hoods to have optimal resistance along the system so that the fan size is not causing high energy consumption. Proper introduction of duct size and other accessories will ensure the system curve intersects with the power optimized fan curve depicting it as the energy and environment conscious solution.

Laboratory Safety System

Chemical and Physical stressors in a laboratory occupational settings can be very imminent in becoming health risk to the workers in the laboratory. Clear definition of the process emitting the airborne hazard in the form of chemical or even heat will enable effective deployment of control hoods such as fume hoods, chemical safety cabinets, exterior extendable arm, safety cabinets, reliable general ventilation with adequate air changes, humidity control and etc.

Maintenance, Repair And Overhaul

System reliability of a control mechanism is vital to ensure the permissible exposure limit to the airborne contaminant are kept in check. We derive a good performance monitoring and periodical assessment to gauge the deterioration in performance from the peak condition below the minimum acceptable range. We establish a good operation and maintenance program based on actual performance trends that will ensure continuous reliability of the engineering control element.

Monthly Inspection & Training.

Deterioration of a system form the peak condition to below acceptable state can only gauge via performance monitoring, periodic monitoring or monthly monitoring. We establish this monthly monitoring and trigger the exact time the system needs to be serviced. This approach will keep the system operation optimised and minimize unwanted stoppage / idle time.

Learn more about industrial ventilation.

Is your ventilation reducing the airborne hazard in the workplace?

This is not justified by the efficiency of the ventilation system via LEV or GEV report but via air concentration testing correlated to the engineering performance report. The results must be lower than Permissible Exposure Limit and meet the original baseline air concentration captured upon installing the system.

What are the airborne hazards the ventilation system is controlling?

Most of the time, the user does not know this as such the application of the ventilation is done so poorly liberating the contaminant away from the source to the breathing zone of the worker making route of entry via respiratory imminent.

E8 Group, Leader in Ventilation Management.

E8 group was incorporated in October 2005 dealing on with Environmental Monitoring which covers all the needs required by Department of Environment and stipulated by Environmental Quality Act. In 2006 we acquired the expertise to work on the area of Industrial Hygiene as to advance our service in safe guarding work.

Contact us.

Have questions about our solution options? Talk with an E8 Group expert to learn how we can support your needs.

Talk to us
enquiry@e8group.com.my
Tel : 03 80248148 / 6149
Fax : 03 80246148

Subang Office
19-1, Jalan USJ 21/6, 47630. Subang Jaya. Selangor.

Southern Office
No 7-1, Jalan Jelutong 1, Taman Desaru Utama, Desaru Utama, 81930 Bandar Penawar, Johor. Tel : 01 23078108